Microsites

Microsites

TAP

Rimmed Hammerset Anchor

Hammerset anchor with metric internal thread M6 - M16 for medium load range for anchoring in non-cracked concrete C20/25 - C50/60 and for multiple fixings of non-load bearing systems in concrete.  

CE Marking
CE Marking
ETA
ETA
New
New
Service class 2
Service class 2
Electro-galvanized steel
Electro-galvanized steel
Fire resistance R 120
Fire resistance R 120
Fix Calc
Fix Calc

Product Details

Images

Features

Material

  • Steel
  • White zinc plated

Benefits

  • Safe and controlled expansion
  • Fast application
  • Shallow embedment depth
  • Rimmed plug version for easy installation flush with base material
  • High strength in relation to embedment depths
  • Fire resistance R120

Application

Applications

  • Suspended ceiling applications
  • Pipework
  • Sprinkler systems

Suitable for

  • Multiple use for non-structural
  • applications on cracked
  • and non-cracked concrete
  • Solid stone

Technical Data

Product Dimension - Rimmed hammerset anchor

Dimensions

ReferenceMetallic fixings dimensionsInstallation data
Product Dimensions[mm]Product ReferenceOtherInstallation data
Plug[mm]Dimensions[mm]Thread length [Lv][mm]Max. thread engagement [Lₛ,ₘᵢₙ][mm]Hole diameter [dₒ][mm]Cylindrical hole depth [h₀][mm]Qty per box[stk]Qty per outer boxNominal embedment depth [hₙₒₘ][mm]Installation torque[Nm]
75205B06000008x25*M6x25116TAP825100.02000254
75205B080000010x30M8x30138TAP1030100.01000308
75205B100300012x30*M10x301210TAP1230100.06003015
75205B100000012x40M10x401710TAP1240100.06004015
75205B120000015x50M12x502112TAP155050.03005035
75205B160000020x65**M16x653016TAP206525.01506560

*  Only ETA 18/0433 ETAG 001 p.6 Multiple use
** Only ETA 18/0432 EAD-330232-00-0601 opt.7

Screw Length: Minimum: Ls,min + tfix  -  Maximum: Lth + tfix

Product Dimension - TAP Setting Tool

Table "Product Dimension - TAP Setting Tool" cannot be displayed : no references available.

tool

ReferenceMetallic fixings dimensions
OtherProduct Reference
Qty per box[stk]
75205B0600000100.0TAP
75205B0800000100.0TAP
75205B1003000100.0TAP
75205B1000000100.0TAP
75205B120000050.0TAP
75205B160000025.0TAP

Design capacities - single anchor - no edge distances - ETA-18/0432

ReferenceMetallic fixings dimensionsMetallic fixings loads
Product Dimensions[mm]Recommended loads - Non-cracked concrete
Dimensions[mm]Bending moment Mᵣₑc[Nm]Tension - Nᵣₑc[kN]Shear - Vᵣₑc[kN]
C20/25[kN]C30/37[kN]C40/50[kN]C50/60[kN]C20/25[kN]C30/37[kN]C40/50[kN]C50/60[kN]
75205B0600000M6x25---------
75205B0800000M8x308.983.344.75.144.95.66.2
75205B1003000M10x30---------
75205B1000000M10x4017.95.16.27.27.96.17.48.69.5
75205B1200000M12x5017.96.17.48.69.58.510.41213.2
75205B1600000M16x6531.379.912.11415.325.230.735.635.9

1. The design loads loads have been calculated using the partial safety factors for resistances stated in ETA-approval(s). The loading figures are valid for unreinforced concrete and reinforced concrete with a rebar spacing s ≥ 15 cm (any diameter) or with a rebar spacing s ≥ 10 cm, if the rebar diameter is 10mm or smaller.
2. The figures for shear are based on a single anchor without influence of concrete edges. For anchorages close to edges (c ≤ max [10 hef; 60d]) the concrete edge failure shall be checked per ETAG 001, Annex C, design method A.
3. Concrete is considered non-cracked when the tensile stress within the concrete is\sigmaL +\sigmaR ≤ 0. In the absence of detailed verification\sigmaR = 3 N/mm² can be assumed (\sigmaL equals the tensile stress within the concrete induced by external loads, anchors loads included).

*Not covered by ETA-18/0432

Recommended capacities - multiple use cracked and un-cracked concrete ETA-18/0433

ReferenceMetallic fixings dimensionsMetallic fixings loads
Product Dimensions[mm]Product Referencetension / shear load Rᵣₑc[kN]
Dimensions[mm]
75205B0600000M6x25TAP0.5
75205B0800000M8x30TAP0.7
75205B1003000M10x30TAP-
75205B1000000M10x40TAP1
75205B1200000M12x50TAP1.4
75205B1600000M16x65TAP-

The design loads FRD derive from the characteristic loads on the ETA certification and are inclusive of the partial safety factors γM

The recommended loads F derive from the characteristic loads on the ETA certification and are inclusive of the partial safety factors γF=1.4 and γM

Installation

Installation

Installation data

ReferenceMetallic fixings dimensionsInstallation data
Product Dimensions[mm]Product ReferenceInstallation data Spacing and edge distances
Dimensions[mm]Wrench size[mm]Ø drilling hole[mm]Min. drill depth[mm]Ø drilling fixture[mm]Installation torque[Nm]Embedment depth[mm]Min. support thickness[mm]
75205B0600000M6x25-TAP8257425-
75205B0800000M8x30-TAP10309830100
75205B1003000M10x30-TAP1240121540100
75205B1000000M10x40-TAP1240121540100
75205B1200000M12x50-TAP1550143550100
75205B1600000M16x65-TAP2065186065130

Spacing and edge distances - ETA-18/0432

ReferenceMetallic fixings dimensionsInstallation data
Product Dimensions[mm]Product ReferenceSpacing and edge distances
Dimensions[mm]Min. spacing[mm]Min. edge distance[mm]Characteristic edge distance[mm]Characteristic spacing(5) - Scr,N[mm]
75205B0600000M6x25TAP150200--
75205B0800000M8x30TAP1502004590
75205B1003000M10x30TAP--60120
75205B1000000M10x40TAP15020060120
75205B1200000M12x50TAP15020075150
75205B1600000M16x65TAP--97195

* Not included in the approval

Certification

Declaration of Performance (DoP)

No history available

European Technical Assessment (ETA)

No history available
No history available

Buy Online

Contact

Simpson Strong-Tie U.K.

Simpson Strong-Tie

Cardinal Point, Winchester Road
Tamworth
Staffordshire
B78 3HG
United Kingdom